Sunways STH 4β12 kW | HV Series
The Sunways STH 4β12 kW (HT) series are three-phase hybrid inverters designed for commercial to large residential installations that require both on-grid and backup capability. They support high-voltage battery systems (wide battery voltage window), fast UPS switching (<10 ms), and robust overload capability (short-term peak output and long-duration overload modes). With a maximum efficiency up to 98.2%, IP65 protection, and flexible battery communication (CAN / RS485), this series targets hybrid solar + storage systems, small commercial sites, shops/offices and residential projects that may scale by adding parallel units or larger battery banks.
Β
π Key Features
β Power range (rated):
4 kW β 12 kW (models: 4KTL, 5KTL, 6KTL, 8KTL, 10KTL, 12KTL)
β Max efficiency
up to 98.2%
β Protection
IP65 (outdoor capable)
βOverload
up to 200% backup output (short-term/peak modes noted)
β Battery voltage range
140β750 V (wide HV battery support)
β MPPT
2 MPPTs (2 inputs total) with wide MPPT voltage range (150β850 V or 200β850 V depending on model)
β UPS switching time
< 10 ms (uninterruptible supply)
β Cooling
Natural convection (quiet, <25 dB)
Model Comparison (Key Ratings)
| Model | Max DC Input Power (W) | Start-up Voltage (V) | Max DC Input Voltage (V) | Rated DC Input Voltage (V) | MPPT Voltage Range (V) |
|---|---|---|---|---|---|
| STH-4KTL-HT-P | 6,400 | 150 | 1,000 | 620 | 150β850 |
| STH-5KTL-HT-P | 8,000 | 150 | 1,000 | 620 | 150β850 |
| STH-6KTL-HT-P | 9,600 | 180 | 1,000 | 620 | 200β850 |
| STH-8KTL-HT-P | 12,800 | 180 | 1,000 | 620 | 200β850 |
| STH-10KTL-HT-P | 16,000 | 180 | 1,000 | 620 | 200β850 |
| STH-12KTL-HT-P | 19,200 | 180 | 1,000 | 620 | 200β850 |
Battery
| Battery Communication | CAN / RS485 |
| Battery Voltage Range | 140β750 V |
| Max Charge / Discharge Current | 25 A / 25 A |
| Built-in Fuse (Rated Current) | 63 A |
Output (Grid Mode)
| Rated Output Power (W) | Max Output Power (W) | Max Apparent Power (VA) | Grid Type | Rated Frequency | Max Output Current (A) |
|---|---|---|---|---|---|
| 4,000 β’ 5,000 β’ 6,000 β’ 8,000 β’ 10,000 β’ 12,000 | 4,400 β’ 5,500 β’ 6,600 β’ 8,800 β’ 11,000 β’ 13,200 | 4,400 β’ 5,500 β’ 6,600 β’ 8,800 β’ 11,000 β’ 13,200 | 3L / N / PE, 230/400 V | 50 / 60 Hz | 6.7 β’ 8.3 β’ 10 β’ 13.3 β’ 16.5 β’ 20 |
Output (Backup Mode)
| Rated Backup Output | Same as Grid Output (4 kW β 12 kW) |
| Max Apparent Backup Power | 4,400 β 13,200 VA |
| Peak Output (60 sec) | 8,000 β 20,000 VA |
| Peak Output per Phase | 1,600 β 5,000 VA |
| UPS Switching Time | < 10 ms |
Efficiency
| Max Efficiency | 98.1% β 98.2% |
| Euro Efficiency | 97.3% β 97.4% |
| MPPT Efficiency | 99.9% |
| Battery Conversion Efficiency | 97.2% β 97.3% |
Protection & General Data
Protection
| DC Reverse Polarity | Integrated |
| Battery Reverse Connection | Integrated |
| Insulation Resistance | Integrated |
| DC Switch | Optional |
| Surge Protection | Integrated |
| Over-Temperature | Integrated |
| Residual Current | Integrated |
| Anti-Islanding | Integrated |
| AC Over-voltage | Integrated |
| Overload | Integrated |
| AC Short-circuit | Integrated |
General Data
| Dimensions (mm) | 550 Γ 410 Γ 175 |
| Weight | 26 β 28 kg |
| Protection Degree | IP65 |
| Night Self-consumption | < 15 W |
| Topology | Transformerless |
| Operating Temperature | β30Β°C ~ +60Β°C |
| Humidity | 0% β 100% |
| Operating Altitude | 4000 m (derating > 3000 m) |
| Cooling | Natural Convection |
| Noise Level | < 25 dB |
| Display | OLED & LED |
| Communication | WiFi / LAN (Optional) |